Steel Structure Fabrication for Factories and Warehouses

Turn structural intent into components that can be fabricated and erected

PT KWD supports factories, warehouses and ancillary buildings in Indonesia with steel detailing, fabrication, protective coating, logistics and site-erection coordination. Project quotations follow drawings, location and the agreed delivery scope.

KWD steel-structure project photo with a blue-and-white roof and steel columns
01

Coordination from shop drawings to erection

02

Factory fabrication and component numbering

03

For factories, warehouses and supporting structures

Define the scope before comparing steel-structure quotations

Steelwork is quoted by project. A price per kilogram or building area alone does not establish the package cost. Separate component supply from site work so quotations cover the same scope.

Send your steel-structure requirements
Project basics
City, building use, length, width, height, span, floor area and target construction schedule.
Drawings and loads
Available design drawings, calculation requirements, connections and load information. A sketch can start the discussion if drawings are incomplete.
Members and coatings
Define detailing, fabrication, material grade, member list, connections, corrosion protection and fire-coating requirements.
Site and delivery scope
Confirm transport, lifting equipment, erection and inspections separately. State in writing whether foundations, civil works, roof and wall cladding are included.
Quantity and pricing basis
Provide estimated tonnage (t) or floor area (m²), noting whether cladding and erection are included. Drawings and the itemized quotation govern.

Drawings can be shared separately during the WhatsApp discussion. Final design and construction conditions require the responsible engineer's approval. This page is not a structural design document or fixed-price commitment.

Structural parameters come from calculations and approved shop drawings

Steel structures are not a single standard product. Sections, plate thickness, connections, corrosion protection and fire requirements must follow the project design and responsible engineer's approval.

ParameterProject range / note
Thickness rangePlate and section thickness determined by structural calculation, connections and available material
Member widthDetailed as H-sections, box sections, trusses or built-up members
Custom lengthSegmented for lifting capacity, containers and road-transport restrictions
Base materialCarbon or low-alloy structural steel; grade confirmed by design and material certificate
Surface treatmentBlast cleaning, primer and topcoat; hot-dip galvanizing or fire coating available where specified
Color rangeTopcoat color confirmed with the project palette, coating system and maintenance plan
Design and execution referencesSNI 1729:2020, SNI 1727:2020 and SNI 1726:2019 may apply; cold-formed members may use SNI 7971:2013. Approved design documents govern

For industrial buildings and production-support structures

01

Industrial factories

Primary frames for wide production spaces, crane support and roof-envelope systems.

02

Warehouses and logistics

Regular grids and standardized members improve fabrication and erection efficiency.

03

Equipment platforms and mezzanines

Detailed around equipment loads, maintenance access and process clearances.

04

Canopies and links

Light steel solutions for loading zones, walkways and building connections.

Numbering, welding and dimensional control connect factory and site

Detailing, cutting, assembly, welding and coating are organized around the intended erection sequence to reduce site identification and rework.

01
Detailing and planning

Break down members, connections and bills of material around the erection sequence.

02
Cutting and assembly

Cut, drill and assemble components to the approved dimensions.

03
Welding and inspection

Complete qualified weld processes and specified visual or test checks.

04
Coating and marking

Apply surface preparation, coating and clear erection marks.

05
Packing and dispatch

Protect and load members in the planned site-lifting sequence.

Lifting stability, temporary bracing and final tightening are essential

Lifting stability, temporary bracing and final tightening are essential

Steel erection is specialist work. It must follow an approved lifting plan, connection procedure and safety plan; temporary support stays until the stable structural system is complete.

  1. 01

    Verify foundation gridlines, levels, anchor bolts and component marks.

  2. 02

    Use planned lifting points, temporary bracing and controlled work-exclusion zones.

  3. 03

    Form a stable bay before final bolt tightening or site welding to the approved procedure.

  4. 04

    Complete alignment, levels, connections, coating touch-up and handover inspection.

What to prepare for a steel-structure enquiry

01Is pricing per kilogram or per square metre?

Quotations may be compared by member weight, building area or package scope, but these bases are not directly interchangeable. Steel grade, span, connections, coating, transport and erection affect the total. Use an agreed material list and itemized quotation.

02Can I enquire without complete construction drawings?

Yes. Start with the location, intended use, length, width, height, span and any sketch. KWD can help identify missing information. Structural parameters, calculations and construction documents still require the responsible engineer's approval; an initial discussion does not replace approved design.

03Are foundations, roofing and erection automatically included?

No scope should be assumed. Confirm foundations and civil works, roof and wall cladding, steel members, coating, transport, lifting equipment and site erection separately, with responsibilities and costs recorded in the quotation.

04How long does project delivery take?

Timing depends on drawing approval, procurement, member quantities, coating requirements, location and site readiness. A fixed delivery time cannot be promised before those details are checked.

05Can the structure be customized?

Yes. Sections, connections, coatings, shipping splits and packing can follow approved drawings, with installation briefings where included.

06What is the warranty period?

Coverage is defined separately for supply, coating and erection scope in the contract. Maintenance, corrosive exposure and third-party work affect applicability.

From roof works to frame connections

Site photographs show roof works, framing and connection details. Design parameters and delivery scope follow each project's approved drawings and contract.

Roof panels and lifting work on site
01

Roof panels and lifting work on site

Interior columns, beams and roof purlins
02

Interior columns, beams and roof purlins

Steel platform framing and connections
03

Steel platform framing and connections

Related resources and project records

Request an engineering quote

Send drawings, span, area, loads and location so we can structure the enquiry.

Tell us about your project

Complete the form and choose a service contact. WhatsApp will open with your selected products prefilled. The form is not stored or sent elsewhere.

Products of interest Required
Steel structure
Estimated quantity or area Optional

Quantities are optional. Enter each product separately, or discuss them with our team.

This opens WhatsApp only. No email is sent and no form data is stored on the website.